Liqui-CultĀ® Microbial Test Kit

Fuel Testing Solution

  • Monitor microbial activity within the fuel tank
  • Accurately quantify bacterial and fungal growth in water, fuel, oil, and other fluids
  • Identify fuel contamination problems before they cause fuel reliability issues
Get Product Pricing
Product Details
Product Instruction
Support Documents
Liqui-CultĀ® Fuel Test Kits are an excellent tool to monitor fuel tanks for microbial contamination. Liqui-CultĀ® can be used in the lab or office environment to accurate detect and quanitfy bacterial and fungal growth in water, fuel, oil, and other fluids. Using Liqui-CultĀ® as part of a regular fuel maintenance program will help users identify fuel contamination before it can pose serious problems to one fuel system.

Liqui-CultĀ® Product Info:

Contents
Sealed Test Bottles (x10), Syringes (x10), Instructions
Weight
48 oz.
Dimensions
10 Ɨ 6 Ɨ 3 in
  1. Collect a fuel sample in a clean, dry container.
  2. Remove the center seal from the metal cap of a test bottle. Unwrap the syringe, remove the needle guard, and insert the needle into the fuel sample. Draw the plunger and fill the syringe with 5CC of fuel.
  3. Insert the needle through the rubber cap on the bottle and inject the sample into the test bottle. Remove the needle from the bottle, replace the needle guard, and discard the syringe according to local, state, and federal guidelines. Shake the test bottle vigorously to mix.
  4. Incubate the bottle at room temperatureĀ 68Ā°-75Ā°F (20Ā°-24Ā°C)Ā for 30 hours. Protect from light. Do not refrigerate.Ā 
  5. After 30 hours, inspect the test bottle for bacterial growth. Use the image below for reference.Ā 
  6. At 72 hours, Inspect the test bottle for fungal growth. Use the image below for reference.
  7. Once you complete your inspection, fill the bottle with bleach under a fume hood and let it stand for 24 hours. Discard appropriately.

Bacterial Growth Reference:

After 30 hours, compare the color density of the sample bottle to this color chart.

Fungal Growth Reference:

After 72 hours, compare the color density of the sample bottle to this color chart.

Product Specifications

Liqui-CultĀ® Fuel Test Kits are an excellent tool to monitor fuel tanks for microbial contamination. Liqui-CultĀ® can be used in the lab or office environment to accurate detect and quanitfy bacterial and fungal growth in water, fuel, oil, and other fluids. Using Liqui-CultĀ® as part of a regular fuel maintenance program will help users identify fuel contamination before it can pose serious problems to one fuel system.

Liqui-CultĀ® Product Info:

Contents
Sealed Test Bottles (x10), Syringes (x10), Instructions
Weight
48 oz.
Dimensions
10 Ɨ 6 Ɨ 3 in

Product Instructions

1. Collect a fuel sample in a clean, dry container.
2. Remove the center seal from the metal cap of a test bottle. Unwrap the syringe, remove the needle guard, and insert the needle into the fuel sample. Draw the plunger and fill the syringe with 5CC of fuel.
3. Insert the needle through the rubber cap on the bottle and inject the sample into the test bottle. Remove the needle from the bottle, replace the needle guard, and discard the syringe according to local, state, and federal guidelines. Shake the test bottle vigorously to mix.
4. Incubate the bottle at room temperature 68Ā°-75Ā°F (20Ā°-24Ā°C) for 30 hours. Protect from light. Do not refrigerate.
5. After 30 hours, inspect the test bottle for bacterial growth. Use the image below for reference.
6. At 72 hours, Inspect the test bottle for fungal growth. Use the image below for reference.
7. Once you complete your inspection, fill the bottle with bleach under a fume hood and let it stand for 24 hours. Discard appropriately.

Bacterial Growth Reference:

After 30 hours, compare the color density of the sample bottle to this color chart.

Fungal Growth Reference:

After 72 hours, compare the color density of the sample bottle to this color chart.